Smart Process Gating
Leuze electronic GmbH + Co. KG
MLC 530 SPG
20
Operating mode
Functions
1
4
5
6
Protective-field filter time
Brief clearing of the protective field (1 s or 2 s) is possible with-
out interruption of the gating event. Small gaps in the load can
thereby be tolerated.
2 s
0.5 s
1 s
2 s
Max. conveyor speed without additional measure
0.1 m/s
0.4 m/s
0.2 m/s
0.1 m/s
Qualified stop
■
■
■
Partial gating
■
The following SPG functions are available in all SPG operating modes:
• Gating termination by the control (see chapter 4.5.1 "Controlled gating end")
• Gating timeout extension (see chapter 4.5.2 "Gating timeout extension")
• Gating sequence reset (see chapter 4.5.3 "Gating sequence reset")
• Gating restart (see chapter 4.5.4 "Gating restart")
• Override (see chapter 4.5.5 "Override")
NOTICE
The following general functions of the MLC safety light curtains are available in all SPG operat-
ing modes (see chapter 5 "Functions"):
Start/restart interlock (RES)
Transmission channel changeover
Operating range selection
Signal output
Blanking