EtherCAT interface
Leuze electronic GmbH + Co. KG
AMS 338
i
71
TNT
35/7-2
4V
Object 2025
h
Configuration of dynamic velocity monitoring
Sub-index 01
Bit 0: Switching type
0 = Velocity above upper limit
1 = Velocity below lower limit
Bit 1: Direction selection
0 = Velocity monitoring not direction-dependent
1 = Velocity monitoring direction-dependent
Bit 2: Velocity monitoring
0 = Deactivated
1 = Activated
Bit 3 - Bit 7: Reserve
Object 2026
h
Velocity status
Bit 0: Velocity measurement error
0 = OK
1 = Error
Index
Sub-
index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
2025
01
Limit value
check
u 8
rw
0
7
0
See below
02
Velocity
limit
value 1
u 16
rw
0
20000
0
mm/s or
(in/100)/s
03
Hystere
-
sis of
velocity
limit value
1
u 16
rw
0
20000
100
mm/s or
(in/100)/s.
04
Monitor
-
ing as of
position
start
int 32
rw
-999999
999999
0
mm or in/100
05
Monitor
-
ing up to
position
end
int 32
rw
-999999
999999
0
mm or in/100
Index
Sub-
index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
2026
--
Velocity
status
u 32
ro
--
--
--
See below