Display and control panel AMS 338i
Leuze electronic GmbH + Co. KG
AMS 338
i
45
TNT
35/7-2
4V
8.3
Menu description
8.3.1
The main menus
After voltage has been applied to the laser, device information is displayed for several
seconds. The display then shows the measurement window with all status information.
AMS 338i 120
Leuze electronic
GmbH & Co. KG
SW: V 1.3.0 HW:1
SN: ---------------
Device information - main menu
This menu item contains detailed information on
• Device type
• Manufacturer
• Software and hardware version
• Serial number
No entries can be made via the display.
Network information
Address:
1
Alias:
1
Status:
INIT, PRE, SAFE, O
P
Network information - main menu
• Explanations of address, alias, status.
No entries can be made via the display.
IO1 LSR PLB
ECAT
IO2 TMP ATT
ERR
+ 87.000m
Status and measurement data - main menu
• Display of status, warning and error messages.
• Status overview of the switching inputs/outputs
• Bar graph for the received signal level.
• Link
• Measurement value
No entries can be made via the display.
See "Indicators in the display" on page 40..
Parameter
Parameter handling
EtherCAT
Position value
I/O
Other
Parameter - main menu
• Configuration of the AMS.
See "Parameter menu" on page 46.
Language selection
o Deutsch
o English
o Español
o Français
o Italiano
Language selection - main menu
• Selection of the display language.
See "Language selection menu" on page 50.
Service
Status messages
Diagnosis
Expanded diagnosis
Service - main menu
• Display of status messages.
• Display of diagnostic data.
No entries can be made via the display.