EtherCAT interface
80
AMS 338
i
Leuze electronic GmbH + Co. KG
Note!
Password activation must be set to ON.
Explanation regarding sub-index 06 "Heating control"
0 = Standard (10°C … 15°C)
1 = Extended (30°C … 35°C)
Note!
Sub-index 06 is available as standard, but functions only for devices with integrated heating
(
AMS 338
i
… H).
Sub-index 06 defines a switch-on/switch-off range for the heating control. The extended
switch-on/switch-off range for heating may provide a remedy in the event of condensation
problems. Due to the limited heating capacity, it cannot be guaranteed that no condensation
will form on the optics in the extended switch-on/switch-off range.
9.7.7
Objects of AMS 338
i
from encoder profile DS406 Class 1
The AMS 338
i
applies the profile from CANopen. The profile allocates specified properties
of the participant to defined object addresses.
The AMS 338
i
communicates in accordance with the specifications in the profile "DS406"
Class 1.
For Class 1, it is essential to describe the following objects.
Object 6000
h
Operating parameter
02
Display
illumina
-
tion dura
-
tion
u8
rw
0
1
0
0 = Off after
10min.
1 = Always on
03
Display
contrast
u8
rw
0
2
1
0 = Low
1 = Medium
2 = High
04
Password
activation u8
rw
0
1
0
0 = OFF
1 = ON
05
Password u16
rw
0000
9999
0000
Setting of
4
-
digit password
06
Heating
control
u8
rw
0
1
0
See below
Index
Sub-
index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
Index
Sub-
index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
6000
--
Operating
parame
-
ters
u16
rw
--
--
--
See below