Display and control panel AMS 338i
46
AMS 338
i
Leuze electronic GmbH + Co. KG
Note!
The rear cover of this manual includes a fold-out page with the complete menu structure. It
describes the menu items in brief.
8.3.2
Parameter menu
Parameter handling submenu
The following functions can be called up in the
Parameter handling
submenu:
• Lock and enable parameter entry
• Set up a password
• Reset the AMS 338
i
to the default settings
Additional important information on parameter handling can be found at the end of the
chapter.
EtherCAT submenu
Note regarding the second station address - in short SSA- (formerly station alias)
The SSA is a freely configurable position-independent address which is often used for the
so-called hot connect. The values range from 0 to 65535. The SSA is persistently stored on
the AMS 338
i
and is available after the next start-up. A second option is to write the SSA to
Table 8.1:
Parameter handling submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Parameter
enable
ON/OFF
The standard setting (
OFF
) prevents unintended parameter
changes.
With parameter enable activated (
ON
), the display is inverted.
In this state, it is possible to change parameters manually.
OFF
Password
Activate
password
ON/OFF
To enter a password, parameter enable must be activated.
If a password is assigned, changes to the AMS 338
i
can only
be made after the password is entered.
The master password 2301 overrides the individually set
password.
OFF
Password
entry
For setting a four-digit numerical password.
Parameters to
default
By pressing the enter button
after selecting
Parameters to default
, all parameters are reset to their standard
settings without any further security prompts.
In this case, English is selected as the display language.
Tabelle 8.2: EtherCAT submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Activation
ON/OFF
ON
Address
(station alias)
Configuration option 0 - 65535
0