EtherCAT interface
74
AMS 338
i
Leuze electronic GmbH + Co. KG
Bit 11: Intensity monitoring (ATT)
If the intensity of the reception signal drops below the defined limit value, the output is set.
0 = OFF
1 = ON
Bit 12: Temperature monitoring (TMP)
If the internal device temperature is outside the defined limit values, the output is set.
0 = OFF
1 = ON
Bit 13: Laser prefailure monitoring (LSR)
If the laser power drops below the defined limit value, the output is set.
0 = OFF
1 = ON
Bit 14: Plausibility monitoring (PLB)
If implausible measurement values are diagnosed, the output is set.
0 = OFF
1 = ON
Bit 15: Hardware error (ERR)
If a hardware error is diagnosed, the output is set.
0 = OFF
1 = ON
Bit 16 - Bit 23: Reserve
0 = Reserve
1 = NC
Bit 24 - bit 26: Function of I/O 1 when defined as input
Value 000 = No function
Value 001 = Preset teach, valid for static (object 2001) and dynamic (object 2002) pre
-
set
Value 010 = Laser OFF. Laser diode is switched off
Bit 27 - Bit 31: Reserve
0 = Reserve
1 = NC
Object 2051
h
Configuration of I/O 2
The settings in "bold" are the default settings.
Index
Sub-
index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
2051
--
I/O2
u32
rw
--
--
--
See below