EtherCAT interface
Leuze electronic GmbH + Co. KG
AMS 338
i
75
TNT
35/7-2
4V
Bit 0: Function of I/O 2 connection on PWR M12
0 = Input
1 = Output
Bit 1: activation
If I/O 2 is defined as input (see bit 0):
0 = 1 - 0 transition
1 = 0 - 1 transition
If I/O 2 is defined as output (see bit 0):
0 = low active (the output is set to 0 if the event occurs)
1 = high active (the output is set to 1 if the event occurs)
Bit 2 - Bit 7: Reserve
0 = Reserve
1 = NC
Note!
Bit 8 to bit 23 affect the "OR" linked output.
Bit 8: Position limit value 1
If the position value is outside of configured limit value 1, the output is set.
0 = OFF
1 = ON
Bit 9: Position limit value 2
If the position value is outside of configured limit value 2, the output is set.
0 = OFF
1 = ON
Bit 10: Velocity limit value
If the velocity value is outside of the configured values, the output is set. The monitoring
processes from objects 2021
h
to 2025
h
are "OR" linked to this bit.
0 = OFF
1 = ON
Bit 11: Intensity monitoring (ATT)
If the intensity of the reception signal drops below the defined limit value, the output is set.
0 = OFF
1 = ON
Bit 12: Temperature monitoring (TMP)
If the internal device temperature is outside the defined limit values, the output is set.
0 = OFF
1 = ON