Technical data
Leuze electronic
ODS 9
66
12.4
Electrical data
Tab. 12.5:
Electrical equipment
Operating voltage U
B
Supply voltage
18 V … 30 V DC
incl. residual ripple
Residual ripple
≤ 15 % of U
B
Open-circuit current
≤ 50 mA
Switching output
Push-pull switching output
NOTE!
The push-pull switching outputs must not be connected in parallel.
Signal voltage high/low
≥ (U
B
- 2 V) / ≤ 2 V
Analog output
ODS9L1.8/LA…
• Voltage
1 V … 10 V / 0 V … 10 V
R
L
≥ 2 kΩ
• Current (factory setting)
4 V … 20 mA, R
L
≤ 500 Ω
IO-Link
COM3 (230.4 baud), Vers. 1.1
min. cycle time: 3 ms
SIO is supported
12.5
Mechanical data
Tab. 12.6:
Mechanical data
Housing
Plastic
Optics cover
Glass
Weight
85 g
Connection type
M12 connector, turnable by 90°
12.6
Environmental data
Tab. 12.7:
Environmental data
Ambient temperature (operation)
-20 °C … +50 °C
Ambient temperature (storage)
-30 °C … +70 °C
Protective circuit
Transient protection
Polarity reversal protection
Short circuit protection for all outputs
VDE protection class
III
Degree of protection with correctly
screwed-on M12 connector
IP67
Standards applied
IEC 60947-5-2