Device description
Leuze electronic
ODS 9
14
Status displays in process mode
Tab. 3.2:
Status displays on the display
Object distance in mm
No measurement value available, e.g. due to a weak or missing
reception signal.
No object detected or reception signal too weak.
No object detected or reception signal too weak.
• Out of Range (+)
• Out of Range (-)
• +max
Sensor deactivated, laser switched off
• Via the input function (see chapter 3.4.1 "Input menu")
• Via the IO-Link command
The current measurement value is less than the lower limit
value of the analog output distance.
The current measurement value is greater than the upper limit
value of the analog output distance.
The measurement value has an offset and/or the gradient is
falling (-1)
Lock function: Button lock activated via IO-Link (device access
locks, bit 3)
The button lock can also be enabled and set using the configu-
ration software
Sensor Studio
:
Configuration > Local operation