Device description
Leuze electronic
ODS 9
23
Preset presetting
Ä
Enter a Preset value via the display or using the
Sensor Studio
configuration software (
IO-Link
):
Application > Distance correction > Preset position
Ä
Position an object at the desired preset distance.
Ä
Perform the preset measurement:
Application > Distance correction > Preset calculation > Execute
ð
The offset value is automatically calculated from the measurement value and nominal measurement
value (preset value) and entered as the offset in the configuration.
Example:
• Entry: preset value 350 mm
• Object distance: 300 mm in front of the sensor
Trigger preset measurement
Distance correction > Preset calculation > Execute
An offset of +50 mm is automatically calculated and stored in the configuration.
• Object distance: 300 mm
Output to display and interface: 350 mm
• Object distance: 400 mm
Output to display and interface: 450 mm