Device description
Leuze electronic
ODS 9
25
3.4.7
Ending configuration
With IO-Link data storage, the behavior upon ending the configuration settings can be changed in the fol-
lowing ways in the
Settings
menu.
Tab. 3.4:
Settings > Exit behavior
Menu item
Use
Display of the menu item
Report to DS
(Report to DS)
Changes in the menu are taken
over in the data memory after
returning to measurement oper-
ation. The
DSUpload
flag is set.
A change was performed and the data memory
updated.
Only local changes
(only local changes)
The change is only temporary or
local on the device or no data
memory is used. The
DSUpload
flag is cleared.
A change was made only locally on the device.
Central storage of configuration data
If the configuration setting is ended with subsequent adoption of the data in the data memory of a con-
nected IO-Link master, the sensor does not need to be newly configured if a device is changed.
The sensor adopts the configuration from the data memory of the connected IO-Link master, provided that
the IO-Link master is capable of doing this and enabled accordingly.
Timeout
If the configuration setting is ended due to a timeout, the previously made changes are always reported by
default to the data memory (Data Storage, DS). If an IO-Link master is connected, the changes are trans-
ferred to its data memory. The status of the
DSUpload
flag is not changed.
If the
DSUpload
flag is not set and the changes are only stored locally, after reconnection the change is
overwritten by the configuration which is stored in the data memory of the connected IO-Link master.
NOTICE
If the sensor is not operated via an IO-Link master, these settings do not need to be made.
3.5
Configuration example
To illustrate menu operation, the setting of the lower switching point of switching output SSC1 to 100 mm is
explained as an example.
Ä
In process mode, press a control button to activate the menu display.
Input
Output SSC1
Ä
Press the navigation button
.
ð
The display shows "Output SSC1" in the upper menu line.
Output SSC1
Output
Ä
Press the enter button
to select Output SSC1.
SSC1 SP1 (dist.)
00250 mm