Starting up the device
Leuze electronic
ODS 9
44
IO-Link system commands
Value
hex / dec
Command
Description
0x41 / 65
Teach SP1
Teach the far setpoint.
0x42 / 66
Teach SP2
Teach the near setpoint.
0x4B / 75
Custom Teach: window
Teach both setpoints.
0x4C / 76
Custom Teach: SP1a
Teach the alternative far setpoint.
0x80 / 128
Device Reset
Restart operating software.
0x82 / 130
Restore Factory Settings
(Factory Reset)
Reset non-volatile user settings to factory set-
tings.
0xA0 / 160
ClearDsUploadFlag
Delete the
DsUpload
flag.
Delete identifier "Accept sensor configuration in
master" again.
Counterpart to command 0xA1 ParamDownload-
Store.
After reconnecting, the sensor configuration is
again overwritten by the configuration in the data
storage of the master.
0xA1 / 161
ParamDownloadStore
Set the
DsUpload
flag.
End sensor configuration to indicate acceptance
in data storage (set
DsUpload
flag) and, if appli-
cable, trigger data storage via event.
0xC0 / 192
Teach Analog Min
Teaches the distance value to which the lower
analog limit value (4 mA, 1 V or 0 V) is assigned.
TP -> AnalogRangeMin.
0xC1 / 193
Teach Analog Max
Teaches the distance value to which the upper
analog limit value (20 mA, 10 V) is assigned. TP
-> AnalogRangeMax.
0xC2 / 194
Teach Preset to Offset
Offset = Preset-TP.
At the time the calculation is performed, the off-
set is corrected so that the (nominal) value
stored under Preset is output.
0xD0 / 208
Activation HighPrio
Activation of the sensor (laser or measurement
on
) with higher priority than the
Transducer Dis-
able
bit in PDout.
If
activate
or
deactivate
was selected as the in-
put function, the input has priority over all other
requirements.
0xD1 / 209
Deactivation HighPrio
Deactivation of the sensor (laser or measure-
ment
off
) with higher priority than the
Trans-
ducer Disable
bit in PDout.
If
activate
or
deactivate
was selected as the in-
put function, the input has priority over all other
requirements.
0xD2 / 210
ActivationDeactivation Std-
Prio
The
Transducer Disable
bit in PDout takes effect
again after system command
208
or
209
.
If
activate
or
deactivate
was selected as the in-
put function, the input has priority over all other
requirements.