Technical data
Leuze electronic
MSI-TRMB
43
14
Technical data
14.1 General specifications
Table 14.1:
Safety-relevant technical data
Table 14.2:
Electrical data, degree of protection, environment, cable data
Type in accordance with IEC 61496
Type 4
SILCL in accordance with IEC 62061
SILCL 3
Performance Level (PL) in accordance with ISO 13849-1
Up to PL e
Category in accordance with ISO 13849-1
Category 4
Probability of a dangerous failure per hour (PFH
d
)
2.15x10
-9
1/h
Mean time to dangerous failure (MTTF
d
)
> 100 years
Mission time (T
M
)
20 years
Operating voltage U
b
+24 V DC
20 % (SELV)
Voltage range
80 - 125 %
Residual ripple
< 15 %
Power consumption at UB without load
< 3 W
Current consumption
Approx. 200 mA
Response time
130 ms
Sensor response time on test request
0.5 … 8.5 ms
Protection class
III
Degree of protection of housing and terminals
IP20 (only suitable for use in operating rooms/cabi
-
nets with minimum protection degree of IP54)
Ambient temperature, operation
–25 … +55 °C
Ambient temperature, storage
–25 … +75 °C
Relative humidity (non-condensing)
< 75 %
Impact resistance
10 g
Dimensions
Weight
Max. 155 g
Conductor connection (wire)
0.2 mm² … 1.5 mm²
Tightening torque for connection terminals
0.5 … 0.6 Nm
Max. cable lengths (reset circuit)
250 m
Example for max. cable length, for:
Conductor cross section
1.5 mm²
Capacity
150 nF/km