Device description
Leuze electronic
MSI-TRMB
13
On
Flashing
alternately
Off
With E-Stop/protective door
application: When switching
on power supply, signals at
S12 and S22 have different
values
Disconnect device from
power supply, check for wir
-
ing faults, replace device if
defective or check con
-
nected ESPE
Problems with detection of
operating mode:
Signal at S32 cannot be
clearly allocated
Problems with detection of
operating mode:
Bridge / signal at S12 cannot
be clearly allocated
Application - connection of
ESPE: Bridge S21-S12 was
removed during operation
Wiring at S32 was changed
during operation or S32 has
short-circuited to VCC/GND
during operation
On
Flashing
alternately
Flashing
alternately
Optical short-circuit existed
during teach-in and was
removed later
Disconnect device from
power supply, check wiring
and connected ESPE
LED indicator
Errors and possible causes Remedial measures
Fault
IN1, IN2
OUT1, OUT2