Device description
Leuze electronic
MSI-TRMB
10
3
Device description
The MSI-TRMB safety relays can be used as follows:
• Safety monitoring devices for electro-sensitive protective equipment (ESPE) on machines which
pose a risk of injury (according to IEC 61496-1),
• Safety sequential device for 2-channel E-Stop monitoring, safety sequential device for 2-channel
safety door monitoring.
As part of the electrical equipment, they enable machines or systems to achieve a safe state before
persons can be endangered.
The safety relay is intended for DIN rail mounting and is wired via 16 terminals. It must be installed in a
housing or switch cabinet (IP54 or higher).
The complete safety system consists of a safety relay and safety sensors connected to it.
a
Reset / device reset (if software reset using start button as described under 4.8 is not desired)
b
Active
c
Transmitter
d
Receiver
e
Start application see chapter 4.1 "Operating mode 1 AOPD", (here: operation with start/restart inter
-
lock)
f
Operating mode: safety monitoring device with one or more protective sensors connected in series
g
EDM (contactor monitoring / external device monitoring circuit)
h
OSSD safety switching output (cross-circuit protection of both outputs by means of polarity reversal
to i)
i
OSSD safety switching output (cross-circuit protection of both outputs by means of polarity reversal
to h)
j
“Error”
Figure 3.1: Structure of the complete safety system
0V
Var. B
Var. A
+2
4
V
State
Er
ro
r
MSI-TRMB
active
Receiver
0V
+
2
4V
Betriebsart
-K1
-K2
-A3
6
S11 S22
S12
S36
S35
S31 14
24
13
23
S21
-K2
-K1
-K1
-K2
A1
A2
-K1
A1
A2
-K2
1
2
1
2
4
4
3
-A2
1
A1
0V
+ 24V
PE
L-
L+
+ 24V
0V
PE
L+
L-
3
1
Transmitter
-A1
a
b
d
c
f
e
g
i
i
h
h
j
+2
4
V
0V
Reset
Start
Start-
Applikation:
Überwachter
Start