Electrical connection
Leuze electronic
MSI-TRMB
24
Table 7.1:
Terminal assignments
Configuration of start application
Further information see chapter 4.7.
Table 7.2:
Configuration of start application
ª
Trigger a reset (software reset via the start button if the device is in the error state, or by briefly switching
off the voltage supply to A1).
The new settings are accepted.
Terminal Function “1 AOPD”:
one or more protective sen
-
sors connected in series
Function “2 AOPD”:
Two rows each with at least
one protective sensor
ES/E-Stop function or SG/
safety door function
S11
Control output /
transmitter connection
Control output /
transmitter connection 1
Control output /
connection of E-Stop or
safety door channel 1
S12
Function identifier:
Bridge S12 to S21
Safety input / transmitter 1
Safety input /
connection of E-Stop or
safety door channel 1
S21
Control output /
transmitter connection 2
Control output /
connection of E-Stop or
safety door channel 2
S22
Safety input /
receiver
Safety input /
receiver 2
Safety input /
connection of E-Stop or
safety door channel 2
S31
Semiconductor output
ERROR
Semiconductor output
ERROR
Semiconductor output
ERROR
S32
Function identifier:
not connected
Function identifier:
not connected
Function identifier:
Bridge to S11
S33
Start application: automatic
and non-monitored start
(restart interlock)
Start application: automatic
and non-monitored start
(restart interlock)
Start application: automatic
and non-monitored start
(restart interlock)
S34
A1
+24 V
+24 V
+24 V
S35
Start application: monitored
start (restart interlock)
Start application: monitored
start (restart interlock)
Start application: monitored
start (restart interlock)
S36
A2
GND
GND
GND
13
OSSD-1
OSSD-1
OSSD-1
14
23
OSSD-2
OSSD-2
OSSD-2
24
Function
Terminals
Operation with start/restart interlock (monitored
start)
Start button between terminal S35 and S36
Non-monitored start / automatic start
Start button / bridge between terminal S33 and S34