Mounting
Leuze electronic
MSI-TRMB
22
Figure 6.5: Arrangement of the deflecting mirrors
6.1.4 Checklist – mounting the protective sensor
Interval: once prior to establishing the electrical connection
Tester: competent person
Table 6.3:
Checklist – mounting the protective sensor
Items on the check list
Yes
No
Do the beam heights satisfy the requirements acc. to ISO 13855 (see table 6.1)?
Is the safety distance to the point of operation maintained (see chapter 6.1.1 "Calcula
Is the minimum distance to reflective surfaces maintained (see chapter 6.1.3 "Minimum
distance to reflective surfaces")?
Is it ensured that protective sensors cannot mutually influence one another?
Can the point of operation or the danger zone only be accessed through the protective
field?
Is it ensured that the protective field cannot be circumvented?
Do the transmitter and receiver connections point in the same direction?
Is the protective sensor mounted acc. to the corresponding instructions provided by the
manufacturer?
Is the protective sensor accessible for testing and replacing?
Is it ensured that the start/restart button cannot be activated from within the danger
zone?
Can the entire danger zone be seen from the installation site of the start/restart button?