Display and control panel AMS 348i
43
AMS 348
i
Leuze electronic
Notice!
The rear cover
of this manual includes a
fold-out page
with the complete
menu structure
.
It describes the menu items in brief.
A detailed description of the individual parameters can be found in the description of the
PROFINET GSD modules (see chapter 9.9.2 "Overview of the GSD modules").
Attention!
If parameters are changed via the display during bus operation, the AMS 348
i
is separated
from the PROFINET at the moment parameter enabling is activated via the display.
Parameters set by the PROFINET are moved to the background, and changes to
parameters can be made via the display. When parameter enabling is exited, the AMS 348
i
is automatically reconnected to the PROFINET. Upon connection to the PROFINET, the
AMS 348
i
receives all parameters from the PROFINET Controller (PLC).
Changes made via the display are overwritten!
Device settings for operating the AMS 348
i
on the PROFINET are managed and
configured exclusively by the PROFINET Controller (PLC).
IO1
LSR
PLB
LNK0
IO2 TMP
ATT
LNK1
ERR
+ 87.000 m
Status and measurement data - main menu
• Display of status-, warning-, and error messages.
• Status overview of the switching inputs/outputs.
• Bar graph for the reception level.
• Link.
• Measurement value.
No entries can be made via the display.
See "Indicators in the display" on page 37.
Parameter
Parameter handling
PROFINET
Position value
I/O
Other
Parameter - main menu
• Configuration of the AMS.
See "Parameter menu" on page 44.
Language selection
o Deutsch
o English
o Español
o Français
o Italiano
Language selection - main menu
• Selection of the display language.
See "Language selection menu" on page 47.
Service
Status messages
Diagnostics
Expanded diagnostics
Service - main menu
• Display of status messages.
• Display of diagnostic data.
No entries can be made via the display.
See "Service menu" on page 48.