Display and control panel AMS 348i
39
AMS 348
i
Leuze electronic
Position value
The measured position value is displayed in the configured unit of measurement.
+87.000 m
With the
metric
setting, the measurement value is always displayed in meters
with
three decimal places
.
+87.0 in
With the
inch
setting, the measurement value is always displayed in inches
with
one decimal place
.
8.2.2
LED status displays
PWR LED
Off
Device OFF
- No supply voltage
Flashing green
Power LED flashes green
- No measurement value output
- Voltage connected
- Self test running
- Initialization running
- Parameter download running
- Boot process running
Green continuous light
Power LED green
- AMS 348
i
ok
- Measurement value output
- Self test successfully finished
- Device monitoring active
Red flashing
Power LED flashes red
- Device ok but warning message (ATT, TMP, LSR)
set in display
- Light beam interruption
- Plausibility error (PLB)
Red
continuous light
Power LED red
- No measurement value output; for details, see Display
Orange
flashing
Power LED flashes orange
- PROFINET wave function