Specifications
Leuze electronic
AMS 348
i
12
TNT
35/7-2
4
V
4
Specifications
4.1
Specifications of the laser measurement system
4.1.1
General specificationsAMS 348
i
Measurement data
AMS 348
i
40 (H) AMS 348
i
120 (H) AMS 348
i
200 (H) AMS 348
i
300 (H)
Measurement range
0.2 … 40 m
0.2 … 120 m
0.2 … 200 m
0.2 … 300 m
Accuracy
± 2 mm
± 2 mm
± 3 mm
± 5 mm
Consistency
1)
0.3 mm
0.5 mm
0.7 mm
1.0 mm
Light spot diameter
40 mm
100 mm
150 mm
225 mm
Measurement value output
1,7 ms
Integration time
8 ms
Resolution
adjustable, see chapter of the individual interfaces
Temperature drift
0.1 mm/K
Ambient temperature sensitivity
1 ppm/K
Air pressure sensitivity
0.3 ppm/hPa
Traverse rate
10 m/s
Electrical data
Supply voltage Vin
2)
18 … 30 V DC
Current consumption
without device heating:
250 mA / 24 V DC
with device heating:
500 mA / 24 V DC
Optical data
Transmitter
laser diode, red light, wavelength 650 … 690 nm
Laser class
2 acc. to EN 60825-1, CDRH
Laser life expectancy
3)
average temperature / year
50 °C: 23.000 h
25 °C: 60.000 h
20 °C: 75.000 h
10 °C: 120.000 h
Interfaces
Interface type
PROFINET-RT with integrated switch
for BUS IN and BUS OUT
Protocol
PROFINET-RT communication
Conformance Class
B
Operating and display elements
Keyboard
4 buttons
Display
monochromatic graphical display, 128 x 64 pixels
LED