PROFINET interface
85
AMS 348
i
Leuze electronic
9.9.3.28 Module 13: Static velocity limit value 3
PROFINET module identifier
Module-ID 1013
Submodule-ID 1
Description
The
static velocity limit value 3
function compares the current velocity with a velocity
stored in the configuration. This occurs in the configured range, which is defined by
range
start
and
range end
.
Notice!
Further explanations on the “Range start” and “Range end” parameters see chapter 9.9.3.26
"Module 11: Static velocity limit value 1".
Parameters
Input data
None
Output data
None
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Switching
mode
Condition for the "velocity limit value 3"
signal, which applies to the output
(module 4/5) and the status bit (module
16).
0.0
Bit
0: Value greater than limit
1: Value less than limit
0
–
–
Direction
selection
Selection of direction-dependent or
direction-independent limit value
checking.
0.1
Bit
0: Direction independent
1: Direction dependent
0
–
–
Velocity limit
value 3
Limit value is compared to the current
velocity.
1…2
unsign
16 bit
0 … 20000
0
mm/s
(in/
100)
/s
16f
Velocity
hysteresis 3
Relative shift to prevent signal
bouncing.
3…4
unsign
16 bit
0 … 20000
100
mm/s
(in/
100)
/s
–
Limit value 3
range start
The velocity limit value is monitored
beginning at this position.
5…8
sign
32 bit
-999999 … +999999
0
mm
in/
100
–
Limit value 3
range end
The velocity limit value is monitored up
to this position.
9
…
12
sign
32 bit
-999999 … +999999
0
mm
in/
100
–
Parameter length: 13 bytes
a
b
c
d
e
f