PROFINET interface
Leuze electronic
AMS 348
i
90
TNT
35/7-2
4
V
9.9.3.32 Module 18: Other
PROFINET module identifier
Module-ID 1018
Submodule-ID 1
Description
General operating parameters such as display language, lighting and contrast, password,
heating control, etc. are set in this module.
Parameters
Input data
None
Output data
None
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Language
selection
Language selection for the display.
A language which was selected via the
display is overwritten by this
parameter.
0.0
…
0.2
Bit
000=0: English
001=1: German
010=2: Italian
011=3: Spanish
100=4: French
0
–
–
Display
illumination
Off after 10 min. or always on.
0.3
Bit
0: Off after 10 min.
1: Always on
0
–
–
Display
contrast
Contrast setting of the display.
The contrast changes under extreme
ambient temperatures and can be
adjusted with this parameter.
0.4
…
0.5
Bit
000=0: Weak
001=1: Medium
010=2: Strong
1
–
–
Password
protection
Password protection on/off.
0.7
Bit
0: OFF
1: ON
0
–
–
Password
Specifies the password.
Password protection must be on.
1…2
unsign
16 bit
0000 … 9999
0000
–
–
Heating
control
Defines a switch-on/switch-off range
for the heating control. The extended
switch-on/switch-off range for heating
may provide relief in the event of con-
densation problems. There is no guar-
antee that no condensation will occur
on the optics in the extended switch-
on/switch-off range due to the limited
heating capacity.
This parameter is available as stan-
dard, but functions only for devices with
integrated heating (AMS 348
i
… H).
3.0
Bit
0 = Standard
(10 °C … 15 °C)
1 = Extended
(30 °C … 35 °C)
0
–
–
Parameter length: 4 bytes
a
b
c
d
e
f