Display and control panel AMS 348i
Leuze electronic
AMS 348
i
44
TNT
35/7-2
4
V
8.3.2
Parameter menu
Parameter handling submenu
The following functions can be called up in the
Parameter handling
submenu:
• Lock and enable parameter entry
• Set up a password
• Reset the AMS 348
i
to default settings.
Additional important information on parameter handling can be found at the end of the
chapter.
PROFINET submenu
Table 8.1:
Parameter handling submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Parameter
enabling
ON / OFF
The standard setting (
OFF
) prevents unintended parameter changes.
With parameter enabling activated (
ON
), the display is inverted. In this
state, it is possible to change parameters manually. As long as parameter
enabling is activated, the AMS 348
i
is disconnected from the PROFINET.
OFF
Password
Activate
password
ON / OFF
To enter a password, parameter enabling must be activated.
If a password is assigned, changes to the AMS 348
i
can only be made
after the password is entered.
The master password 2301 bridges the individually set password.
OFF
Password
entry
Configuration option of a four-digit numerical password.
Parameters to
default
By pressing the enter button
after selecting
Parameters to default
, all parameters are reset to their
standard settings without any further security prompts.
In this case, English is selected as the display language.
Table 8.2:
PROFINET submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Activation
ON / OFF
Activates or deactivates the AMS 348
i
as an PROFINET participant.
If the AMS 348
i
is deactivated as a PROFINET participant, all subsequent
participants connected via the internal switch (Bus OUT) continue to be
active.
ON