PROFINET interface
Leuze electronic
AMS 348
i
70
TNT
35/7-2
4
V
9.9.3.18 Module 3: Dynamic preset
PROFINET module identifier
Module-ID 1003
Submodule-ID 1
Description
With this module, a preset value can be specified. The specified preset value becomes active
in the position in which preset teaching is performed. The preset value can be adjusted within
the control to meet plant requirements without intervening in the static parameter structure.
Parameters
None
Input data
None
Output data
Output data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Preset teach
Read in the preset value.
0.0
Bit
0
1 Preset teach
–
–
4d
5d
Preset reset
Preset value is deactivated.
Output value=measurement
value+offset.
0.1
Bit
0
1 Preset reset
–
–
4d
5d
Preset
The value is accepted during a
corresponding teach event,
The resolution of the preset value is
independent of the resolution selected in
module 1.
1
sign
32 bit
-999999 … +999999
–
mm
in/100
3a
4d
5d
Output data length: 5 bytes