Display and control panel AMS 348i
Leuze electronic
AMS 348
i
38
TNT
35/7-2
4
V
LSR
Warning - laser prefailure message:
Laser diode old, device still functional, exchange or have repaired.
TMP
Warning - temperature monitoring:
Permissible internal device temperature exceeded / not met.
PLB
Plausibility error:
Implausible measurement value. Possible causes: light beam interruption, outside
of measurement range, permissible internal device temperature considerably
exceeded or traverse rate >10m/s.
Depending on the configuration, either zero or the last valid measurement value is
output at the interfaces.
ATT
Warning received signal:
Laser outlet window or reflector soiled or fogged by rain, water vapor or fog. Clean
or dry surfaces.
ERR
Internal hardware error:
The device must be sent in for inspection.
Bar graph
Indicates the
strength of the received laser light
.
The center bar represents the
ATT
warning threshold. The distance value remains
valid and is output at the interfaces.
If no bar graph is available, the
PLB
status information appears at the same time.
The measurement value has thus been assessed as being implausible. Depending
on the configuration, either zero or the last valid measurement value is output at the
interfaces.
Interface info
"LNK0" and "LNK1" in the display indicate an existing EtherNet connection for BUS IN and
BUS OUT. If the status info "LNK0" or "LNK1" is not displayed although the data line is
connected, the connection is faulty.
The connection status is additionally signaled by a green/orange multicolor LED below the
BUS IN and BUS OUT plug connector, see chapter "LINK LED for BUS IN and BUS OUT".
Display of existing
EtherNet connection
Position value
IO1
LSR
PLB
LNK0
IO2 TMP
ATT
LNK1
ERR
+ 87.000 m