This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
•
FQXSPIO0001L: The connector [PhysicalConnectorElementName] has encountered a
configuration error.
This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0266
User Action:
Complete the following steps until the problem is solved:
1. Make sure the cable is securely connected to the system board.
2. Replace the USB module if the problem still persists.
•
FQXSPIO0003N: A diagnostic interrupt has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic
Interrupt.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0222
User Action:
If the NMI button has not been pressed, complete the following steps:
1. Reboot the system.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
•
FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Timeout.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
48
ThinkSystem ST650 V2 Messages and Codes Reference
Содержание ThinkSystem ST650 V2
Страница 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Страница 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 209: ......