This message is for the use case when an implementation has detected that a Sensor has deasserted a
transition to non-critical from normal.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0521
User Action:
Use StorCLI or LSA to check if there is any warning or critical RAID event.
•
FQXSPEA2002I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0523
User Action:
Use StorCLI or LSA to check if there is any warning or critical RAID event.
•
FQXSPEM4000I: The [arg1] on system [arg2] cleared by user [arg3].
This message is for the use case where a Management Controller Event Log on a system is cleared by a
user.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0020
User Action:
Information only; no action is required.
•
FQXSPEM4001I: The [arg1] on system [arg2] is 75% full.
This message is for the use case where a Management Controller Event Log on a system is 75% full.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Event Log Fullness
SNMP Trap ID: 35
CIM Prefix: IMM CIM ID: 0037
User Action:
Information only; no action is required.
•
FQXSPEM4002I: The [arg1] on system [arg2] is 100% full.
37
Содержание ThinkSystem ST650 V2
Страница 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Страница 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 209: ......
Страница 210: ......