CIM Prefix: PLAT CIM ID: 0224
User Action:
Complete the following steps:
1. Reseat the processor and reboot the server.
2. If problem persists, (Trained technician only) replace the identified processor.
3. If problem persists, contact Lenovo support to Trained technician only) replace the system board.
•
FQXSPIO0006N: A software NMI has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Software NMI.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0228
User Action:
If the NMI button has not been pressed, complete the following steps:
1. Reboot the system.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
•
FQXSPIO0007N: A PCI PERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI PERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0232
User Action:
Complete the following steps:
1. Reseat the adapter on another slot.
2. If problem persists, replace the adapter.
3. If problem persists, contact local service.
•
FQXSPIO0008N: A PCI SERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI SERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0234
User Action:
49
Содержание ThinkSystem ST650 V2
Страница 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Страница 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 209: ......
Страница 210: ......