![Lenovo ThinkSystem ST650 V2 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/lenovo/thinksystem-st650-v2/thinksystem-st650-v2_reference_203246062.webp)
CIM Prefix: PLAT CIM ID: 0508
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure, verify that the DIMMs are installed in the
correct population sequence.
2. Reseat the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. If the DIMMs have been upgraded just prior to the issue, update UEFI to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSPMA2005I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
•
FQXSPMA2007I: Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName] has recovered.
This message is for the use case when an implementation has detected a Memory Scrub failure recovery.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0137
User Action:
Information only; no action is required.
•
FQXSPMA2010I: [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no
longer Throttled.
This message is for the use case when an implementation has detected Memory is no longer Throttled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0143
User Action:
Information only; no action is required.
58
ThinkSystem ST650 V2 Messages and Codes Reference
Содержание ThinkSystem ST650 V2
Страница 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Страница 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 209: ......
Страница 210: ......