This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Ensure the power supply unit is supported and meets the system spec in wattage and efficiency level.
2. Check the event log in XClarity Controller (XCC) Web GUI for details to reseat/reinstall/upgrade the
power supply unit.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system board.
2. If the specified sensor is Planar 12V, ensure the PDB board is installed correctly and check the
XClarity Controller event log for power supply related issues, and resolve those issues.
3. If the problem persists, (Trained technician only) replace the PDB board or system board.
4. Contact local service provider. To locate a reseller authorized by Lenovo to provide warranty service,
go to http://www.ibm.com/partnerworld and click Business Partner Locator.
•
FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Ensure the PSU wattage, PSU efficiency level, and the power supply unit is supported for the system.
96
ThinkSystem ST650 V2 Messages and Codes Reference
Содержание ThinkSystem ST650 V2
Страница 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Страница 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 209: ......
Страница 210: ......