2. Make sure fan and power supply unit is installed correctly and clean.
3. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place, clean, and correctly installed.
4. Make sure that the room temperature is within operating specifications.
5. If the problem still persists and XCC event is related to the power supply unit, please upgrade the
power supply unit with a supported specification.
6. If problem persists, collect Service Data log.
7. Contact Lenovo Support.
•
FQXSPPU0003N: [ProcessorElementName] has Failed with IERR.
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0042
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this Processor error.
2. Reboot system.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
•
FQXSPPU0004M: [ProcessorElementName] has Failed with FRB1/BIST condition.
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0044
User Action:
Complete the following steps:
1. If the system board or firmware was just updated, check the Lenovo support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
•
FQXSPPU0009N: [ProcessorElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Processor Configuration
Mismatch has occurred.
Severity: Error
90
ThinkSystem ST650 V2 Messages and Codes Reference
Содержание ThinkSystem ST650 V2
Страница 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Страница 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Страница 209: ......
Страница 210: ......