Step 2. Press down the release tab and pivot the front fan as shown. Then, take the front fan out of the
chassis.
Figure 45. Front fan removal
After removing the front fan:
1. Install either a new front fan or a fan filler for proper air flow. See “Install a front fan” on page 76.
2. If you are instructed to return the old front fan, follow all packaging instructions and use any packaging
materials that are provided.
Install a front fan
Use this information to install a front fan.
Ground package before opening”
To install a front fan, complete the following steps:
Watch the procedure
. A video of the installation process is available:
• Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Acsjj4tU79GzKnWG316BYn
• Youku:
http://list.youku.com/albumlist/show/id_50483452
Step 1. Touch the static-protective package that contains the new front fan to any unpainted surface on
the outside of the server. Then, take the new front fan out of the package and place it on a static-
protective surface.
76
ThinkSystem ST550 Maintenance Manual