Intrusion switch replacement
Use this information to remove and install the intrusion switch. The intrusion switch informs you that the
server cover is not properly installed or closed by creating an event in the system event log (SEL).
Remove the intrusion switch
Use this information to remove the intrusion switch.
Ground package before opening”
Before removing the intrusion switch:
1. If the server is installed in a rack, extend the server from the rack.
2. Remove the server cover. See “Remove the server cover” on page 68.
3. Remove the PCIe adapter retainer. See “Remove the PCIe adapter retainer” on page 116.
To remove the intrusion switch, complete the following steps:
Watch the procedure
. A video of the removal process is available:
• Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Acsjj4tU79GzKnWG316BYn
• Youku:
http://list.youku.com/albumlist/show/id_50483452
Step 1. Disconnect the cable of the intrusion switch from the system board.
Step 2. Slide the intrusion switch as shown to remove it from the chassis.
Figure 103. Intrusion switch removal
If you are instructed to return the old intrusion switch, follow all of the packaging instructions and use any
packaging materials that are provided.
Install the intrusion switch
Use this information to install the intrusion switch.
134
ThinkSystem ST550 Maintenance Manual
Содержание ThinkSystem ST550 7X09
Страница 1: ...ThinkSystem ST550 Maintenance Manual Machine Types 7X09 and 7X10 ...
Страница 8: ...vi ThinkSystem ST550 Maintenance Manual ...
Страница 36: ...28 ThinkSystem ST550 Maintenance Manual ...
Страница 188: ...180 ThinkSystem ST550 Maintenance Manual ...
Страница 206: ...198 ThinkSystem ST550 Maintenance Manual ...
Страница 210: ...202 ThinkSystem ST550 Maintenance Manual ...
Страница 219: ......
Страница 220: ......