Severity: Error
User Action:
1. Restart the system and retry the operation again.
2. If the problem persists, contact technical support.
•
FQXPMER0003I: RAID configuration cleared successfully
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMER0003M: Failed to erase internal storage drives
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, backplane, and related cables.
2. Check if security function is enabled for the hard disk drives, if yes, disable that and retry the
operation.
3. Ensure device firmware is at the latest level.
4. Restart the system and retry the operation again.
5. If the problem persists, contact technical support.
•
FQXPMER0004I: Internal storage drives erased successfully
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMER0004M: Failed to clear system logs
Severity: Error
User Action:
1. Restart BMC via supported method and reboot the system.
2. Retry this operation again.
3. If the problem persists, contact technical support.
•
FQXPMER0005I: All system logs cleared successfully
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMER0005M: Failed to load UEFI factory default settings
Severity: Error
User Action:
1. Restart BMC via supported method and reboot the system.
2. Retry this operation again.
186
ThinkSystem SR650 V2 Messages and Codes Reference
Содержание ThinkSystem SR650 V2
Страница 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Страница 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......