Table 3. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSFIO0012M
A PCIe system error has occurred on Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The Physical slot number is [arg6].
Error
FQXSFIO0014J
A bad option ROM checksum was detected for the device found at
Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device
is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
Error
FQXSFIO0017M
IFM: Error communicating with the XCC - IFM may not be deployed
correctly.
Error
FQXSFIO0019J
PCIe Resource Conflict [arg1].
Error
FQXSFIO0031M
An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical bay number is [arg6].
Error
FQXSFMA0001M
DIMM [arg1] has been disabled due to an error detected during POST.
[arg2]
Error
FQXSFMA0002M
An uncorrectable memory error has been detected on DIMM [arg1] at
address [arg2]. [arg3]
Error
FQXSFMA0003K
A memory mismatch has been detected. Please verify that the
memory configuration is valid. [arg1]
Error
FQXSFMA0004N
No system memory has been detected. [arg1]
Error
FQXSFMA0005N
Memory is present within the system but could not be configured.
Please verify that the memory configuration is valid. [arg1]
Error
FQXSFMA0008M
DIMM [arg1] has failed the POST memory test. [arg2]
Error
FQXSFMA0009K
Invalid memory configuration for Mirror Mode. Please correct memory
configuration. [arg1]
Error
FQXSFMA0010K
Invalid memory configuration for Sparing Mode. Please correct
memory configuration. [arg1]
Error
FQXSFMA0023M
Error has occurred in NVDIMM flash. NVDIMM backup/restore may
not operate correctly. [arg1]
Error
FQXSFMA0024M
Error has occurred in NVDIMM Supercap. NVDIMM backup/restore
may not operate correctly. [arg1]
Error
FQXSFMA0025M
NVDIMM Supercap has been disconnected. NVDIMM will lose its
backup ability until this is corrected. [arg1]
Error
FQXSFMA0027K
Invalid memory configuration (Unsupported DIMM Population)
detected. Please verify memory configuration is valid.[arg1]
Error
FQXSFMA0028K
Memory Capacity exceeds CPU limit. [arg1]
Error
FQXSFMA0032M
Intel Optane PMEM [arg1] has no remaining spares block.
Error
FQXSFMA0042K
Intel Optane PMEM is not supported by processor of this system.
Error
FQXSFMA0046M
DIMM [arg1] is disabled because it is Intel Optane PMEM that is not
supported on current platform
Error
FQXSFPU0001N
An unsupported processor has been detected.
Error
FQXSFPU0002N
An invalid processor type has been detected.
Error
140
ThinkSystem SR650 V2 Messages and Codes Reference
Содержание ThinkSystem SR650 V2
Страница 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Страница 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......