Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0140
User Action:
Information only; no action is required.
•
FQXSPMA0010J: [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled.
This message is for the use case when an implementation has detected Memory has been Throttled.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0142
User Action:
Complete the following steps until the problem is solved:
1. Check the XCC event log for any fan or cooling related issues and address them first.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place and keep clean.
3. Make sure that the room temperature meets operating specifications.
4. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
Note:
If the device is part of a cluster solution, verify that the latest level of code is supported by the
cluster solution before the update.
5. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
•
FQXSPMA0012M: An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0146
User Action:
Complete the following steps until the problem is solved:
1. Check the XCC event log for any fan or cooling related issues and address them first.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place and keep clean.
3. Make sure that the room temperature meets operating specifications.
4. Make sure that the DIMMs and drive baffles (if applicable) are installed in place.
51
Содержание ThinkSystem SR650 V2
Страница 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Страница 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......