Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0330
User Action:
Complete the following steps until the problem is solved:
1. Reseat the affected adapters and riser card.
2. Update the server firmware (UEFI and XCC) and adapter firmware.
Note:
Some cluster solutions require specific code levels or coordinated code updates.
3. If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster
solution before the update.
4. Replace the affected adapters.
5. Replace the riser card.
6. (Trained service technicians only) Replace the system board.
•
FQXSPIO2002I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
•
FQXSPIO2003I: System [ComputerSystemElementName] has recovered from a diagnostic
interrupt.
This message is for the use case when an implementation has detected a recovery from a Front Panel NMI
/ Diagnostic Interrupt
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0223
User Action:
Information only; no action is required.
•
FQXSPIO2004I: Bus [SensorElementName] has recovered from a bus timeout.
This message is for the use case when an implemenation has detected that a system has recovered from
a Bus Timeout.
Severity: Info
48
ThinkSystem SR650 V2 Messages and Codes Reference
Содержание ThinkSystem SR650 V2
Страница 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Страница 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......