4. Please contact your Local Sales Representative or Authorized Business Partner to order qualified
memory to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
•
FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]
Severity: Info
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does not have qualified memory
installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Please contact your Local Sales Representative or Authorized Business Partner to order qualified
memory to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
•
FQXSFMA0008I: DIMM [arg1] POST memory test failure has been recovered. [arg2]
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFMA0008M: DIMM [arg1] has failed the POST memory test. [arg2]
Severity: Error
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFMA0009I: Invalid memory configuration for Mirror Mode has been recovered. [arg1]
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFMA0009K: Invalid memory configuration for Mirror Mode. Please correct memory
configuration. [arg1]
Severity: Error
User Action:
Complete the following steps:
.
153
Содержание ThinkSystem SR650 V2
Страница 1: ...ThinkSystem SR650 V2 Messages and Codes Reference Machine Types 7Z72 and 7Z73 ...
Страница 4: ...ii ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR650 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......