Figure 122. System board installtion
Step 2. Slide the system board toward the rear of the server to secure it in place. To ensure that the system
board is properly installed, gently tug handle of system board forward, a properly installed system
board will not release and slide forward.
Step 3. Install the TCM/TPM to the system board (see
“Install the TCM/TPM adapter (for Chinese Mainland
).
Step 4. Install each memory module to the same slot on the new system board as on the defective system
board (see
“Install a memory module” on page 80
) until all the memory modules are installed.
Step 5. Install the PHMs (see
“Install a processor and heat sink” on page 105
).
Step 6. Install PCIe riser-card assembly if necessary (see
“Install the PCIe riser-card assembly” on page
Step 7. Install adapters removed earlier (see
“Install an adapter” on page 92
Step 8. Install LOM adapter if necessary (see
“Install the LOM adapter” on page 70
Step 9. Reconnect the cables disconnected earlier.
Step 10. Reinstall the power supplies (see
“Install a hot-swap power supply unit” on page 97
Step 11. Reinstall the drive backplanes (see
“Install a drive backplane” on page 53
).
After installing the system board, complete the following steps:
1. Reinstall the processor and memory expansion tray and expansion tray air baffles (see
processor and memory expansion tray” on page 113
2. Push the power supplies into the bays until they click into place.
3. Install any components that you removed from the failing system board. See the related topics in
“Hardware replacement procedures.”
4. Update the machine type and serial number with new vital product data (VPD). Use the Lenovo XClarity
Provisioning Manager to update the machine type and serial number. See
and serial number” on page 123
.
5. Enable TPM/TCM. See
6. Optionally, enable Secure Boot. See
“Enable UEFI Secure Boot” on page 128
.
122
ThinkSystem SR850P Maintenance Manual
Содержание 7D2F
Страница 1: ...ThinkSystem SR850P Maintenance Manual Machine Types 7D2F 7D2G and 7D2H ...
Страница 8: ...vi ThinkSystem SR850P Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR850P Maintenance Manual ...
Страница 172: ...164 ThinkSystem SR850P Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR850P Maintenance Manual ...
Страница 186: ...178 ThinkSystem SR850P Maintenance Manual ...
Страница 187: ......
Страница 188: ...Part Number SP47A58972 Printed in China 1P P N SP47A58972 1PSP47A58972 ...