Install the front operator panel
Use this procedure to install the front operator panel.
Before installing the front operator panel:
1. Read the safety information and installation guidelines (see
).
2. Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
To install the front operator panel, complete the following steps:
Step 1. Align the panel with the slot on operator panel tray assembly, and slide it in until it clicks into place.
Figure 83. Front operator panel installation
After installing operator panel tray assembly, complete the following steps:
1. Reinstall the operator panel tray assembly (see
“Install the operator panel tray assembly” on page 84
PCIe riser-card assembly and adapter replacement
Use this procedure to remove or install the PCIe riser-card assembly and the adapters.
Remove the PCIe riser-card assembly
Use this procedure to remove the PCIe riser-card assembly.
Before removing the PCIe riser-card assembly:
1. Read the safety information and installation guidelines (see
).
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
“Power off the server” on page 11
).
3. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top
cover, or remove the server from the rack.
4.
Watch the procedure
.
Hardware replacement procedures
87
Содержание 7D2F
Страница 1: ...ThinkSystem SR850P Maintenance Manual Machine Types 7D2F 7D2G and 7D2H ...
Страница 8: ...vi ThinkSystem SR850P Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR850P Maintenance Manual ...
Страница 172: ...164 ThinkSystem SR850P Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR850P Maintenance Manual ...
Страница 186: ...178 ThinkSystem SR850P Maintenance Manual ...
Страница 187: ......
Страница 188: ...Part Number SP47A58972 Printed in China 1P P N SP47A58972 1PSP47A58972 ...