2. Reconnect the power cords and any cables that you removed.
3. Power on the server and any peripheral devices.
M.2 drive and backplane replacement
Use this procedure to remove or install M.2 drives and backplane.
How to adjust the position of the retainer on the M.2 backplane
Use this information to adjust the position of the retainer on the M.2 backplane.
Before you adjust the position of the retainer on the M.2 backplane, complete the following steps:
1. Read the safety information and installation guidelines (see
).
2. Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
To adjust the position of the retainer on the M.2 backplane, complete the following steps:
Step 1. Locate the correct keyhole that the retainer should be installed into to accommodate the particular
size of the M.2 drive you wish to install.
Step 2. Press both sides of the retainer and move it forward until it is in the large opening of the keyhole;
then, remove it from the backplane.
Step 3. Insert the retainer into the correct keyhole and slide it backwards until the nubs are in the holes.
Figure 61. M.2 retainer adjustment
Remove the M.2 backplane
Use this procedure to remove the M.2 backplane.
Before removing the M.2 backplane:
1. Read the safety information and installation guidelines (see
).
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
“Power off the server” on page 11
).
3. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top
cover, or remove the server from the rack.
72
ThinkSystem SR850P Maintenance Manual
Содержание 7D2F
Страница 1: ...ThinkSystem SR850P Maintenance Manual Machine Types 7D2F 7D2G and 7D2H ...
Страница 8: ...vi ThinkSystem SR850P Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR850P Maintenance Manual ...
Страница 172: ...164 ThinkSystem SR850P Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR850P Maintenance Manual ...
Страница 186: ...178 ThinkSystem SR850P Maintenance Manual ...
Страница 187: ......
Страница 188: ...Part Number SP47A58972 Printed in China 1P P N SP47A58972 1PSP47A58972 ...