45
Functioning of set up system
Outriggers are monitored with an inductive switch. There is one switch in each outrigger which
tracks whether an outrigger has been set to the ground or not. Monitoring is based on a spring-
loaded pin, which is pushed up when an outrigger is laid on the ground. Switches location in the
outrigger pictured below (Figure 23 (1)).
Check set-up control always before operating the access platform
.
When all four outriggers are firmly against ground the green automatic levelling signal light will
blink (Figure 7 (19)). Drive outriggers
manually
against ground:
-
If the green automatic levelling signal light will blink before all four outriggers touch the
ground, there is a malfunction or a fault in the system and the operation must be stopped
immediately (excluding the situation where automatic levelling has been activated).
-
Check the function
ing of the outrigger’s inductive switch
from the led-light on the switch: the
light should be lit when the outrigger is off the ground and turned off when the outrigger is
set on the ground.
Figure 23 Outrigger limit switch location (A) and position sensor pin locking screw (A)
ATTENTION! If the set-
up control system doesn’t work correctly, using the
access platform is forbidden! The failure/defect must be repaired before
starting operation.
Содержание 135 NEO
Страница 1: ...Operator and Service manual Version 7 2020 July 2020 ...
Страница 9: ...9 Main dimensions Figure 2 135 NEO Main dimensions side Figure 3 135 NEO main dimensions rear ...
Страница 10: ...10 Reach diagram and support dimensions Figure 4 Reach diagram Figure 5 Support dimensions ...
Страница 59: ...59 Figure 37 Load control of the platform Figure 38 Boom position monitoring ...
Страница 60: ...60 Figure 39 Platform levelling monitoring Figure 40 Outrigger monitoring ...
Страница 61: ...61 Figure 41 Transport position monitoring Figure 42 Prevention of drive function ...
Страница 62: ...62 Figure 43 Selection of the platform control position Figure 44 Selection of the lower control position ...
Страница 63: ...63 Figure 45 Selection of the remote control position Figure 46 Platform emergency stop button override ...
Страница 64: ...64 Figure 47 Platform load monitoring override Figure 48 Override of Safety Functions ...