Platform overload indicator light
This access platform is equipped with automatic platform overload
system which prevents all boom movements in case the 250 kg rated load
is exceeded. Should this happen, there is an audible warning signal and an
indicator light up at the control panel (Figure 7 (10)).
The booms can be
operated again after the overload has been removed from the platform.
If platform overload goes on while platform is moving then lift down, telescope in and slewing
functions are enabled to release the overload situation. If platform overload goes on while
platform is stationary, all movements are disabled until overload is removed.
NEVER OVERLOAD THE PLATFORM!
Dynamic outreach control signal light
This access platform is equipped with dynamic outreach control.
Outreach depends on the actual load on the platform.
-
Red dynamic outreach control signal light (Figure 7 (11)) will blink and
an audible sound alarm can be heard when the telescope boom is
about to reach the current maximum outreach.
-
The frequency of the blinking light as well as the audible sound will increase as the telescopic
boom closes the maximum outreach.
-
When the maximum outreach is achieved red dynamic outreach control signal light will stay
continuously on and:
-
Telescope boom movement out is prevented.
-
Continuous audible sound will signal that the maximum outreach is achieved.
-
If boom is moved while dynamic outreach light is on then telescope reverses automatically if
current outreach is above limits.
Move telescope in to decrease outreach.
Fault light
The fault light will signal errors and faults on the equipment. Possible
faults are divided into two categories based on their severity.
When an
ERROR
occurs, the red fault light will
BLINK
.
-
Equipment can be used with extreme caution.
-
Some features are prevented.
-
If the red fault light blinks, return booms onto their transport positions, perform daily
inspection and remove possible cause of the error.
-
If the problem persists, contact your Leguan dealer.
When a
FAULT
occurs, the red fault light will stay
ON continuously
.
-
Ensure neither emergency stop button is pushed down.
Содержание 135 NEO
Страница 1: ...Operator and Service manual Version 7 2020 July 2020 ...
Страница 9: ...9 Main dimensions Figure 2 135 NEO Main dimensions side Figure 3 135 NEO main dimensions rear ...
Страница 10: ...10 Reach diagram and support dimensions Figure 4 Reach diagram Figure 5 Support dimensions ...
Страница 59: ...59 Figure 37 Load control of the platform Figure 38 Boom position monitoring ...
Страница 60: ...60 Figure 39 Platform levelling monitoring Figure 40 Outrigger monitoring ...
Страница 61: ...61 Figure 41 Transport position monitoring Figure 42 Prevention of drive function ...
Страница 62: ...62 Figure 43 Selection of the platform control position Figure 44 Selection of the lower control position ...
Страница 63: ...63 Figure 45 Selection of the remote control position Figure 46 Platform emergency stop button override ...
Страница 64: ...64 Figure 47 Platform load monitoring override Figure 48 Override of Safety Functions ...