If the emergency buttons are not active, one of the safety components has failed and
prevented the use of the equipment.
-
Return booms on their transport supports, stop working with the equipment and contact
your local Leguan dealer.
Possible errors and faults can be diagnosed with a separate service display (option).
Fault light
BLINKS_INTERMITTENT
(option).
-
Hydraulic oil overheats
-
Stop using the machine and let it cool down
-
Audible signal is given only when machine is running
Inclination sensor indicator light
This access platform is equipped with inclination sensor which alerts when
the inclination of the chassis exceeds the given limits.
If the limits are exceeded while driving an orange indicator light will blink
and give an audible alert can be heard. Drive the machine to more even
surface.
While using booms:
If the
ALARM
limit is exceeded:
-
Orange indicator light will blink, and an audible alert can be heard.
-
Return all booms CAREFULLY on to their transport support
-
Check that the ground is solid enough
-
Re-level
Do not reach, slew or lift the booms when the inclination alert light is on!
RISK OF TIPPING OVER!
Содержание 135 NEO
Страница 1: ...Operator and Service manual Version 7 2020 July 2020 ...
Страница 9: ...9 Main dimensions Figure 2 135 NEO Main dimensions side Figure 3 135 NEO main dimensions rear ...
Страница 10: ...10 Reach diagram and support dimensions Figure 4 Reach diagram Figure 5 Support dimensions ...
Страница 59: ...59 Figure 37 Load control of the platform Figure 38 Boom position monitoring ...
Страница 60: ...60 Figure 39 Platform levelling monitoring Figure 40 Outrigger monitoring ...
Страница 61: ...61 Figure 41 Transport position monitoring Figure 42 Prevention of drive function ...
Страница 62: ...62 Figure 43 Selection of the platform control position Figure 44 Selection of the lower control position ...
Страница 63: ...63 Figure 45 Selection of the remote control position Figure 46 Platform emergency stop button override ...
Страница 64: ...64 Figure 47 Platform load monitoring override Figure 48 Override of Safety Functions ...