33
-
drive prevention
-
speed selector switch
Override of transport position monitoring
The transport position of the booms can be overridden with the override switch in the lower
controls panel. This enables outrigger operation even if the booms are not in transport position
or if the sensor monitoring transport position is faulty.
To activate transport position monitoring override:
1.
Turn the ignition key to platform controls position
2.
Wait for power on signal sound and after that wait two seconds
3.
Within 10 seconds turn the override switch in the lower controls panel to outrigger position
and hold it turned (see 6.3)
4.
A second user is required to turn on electric motor or combustion engine from the platform
control panel
5.
Second user operates the outrigger switches from the platform control panel to raise
outriggers
6.
To drive the access platform the second user operates the joystick from the platform
7.
Release the override switch and lock it with the protecting plate
Override of load control and platform emergency stop switch
There is a safety function’s override
switch in the lower controls panel of the access platform.
With this switch platform load monitoring and platform emergency stop switch can be
overridden in an emergency.
Using the switch is allowed only in an extreme emergency
, for
example when the operator has collapsed on the platform, pressed down the emergency stop
switch and they have to be lowered immediately for their safety.
The manufacturer is not
responsible for repercussions of misusing this function!
The override switch is in the lower
controls panel and works only when lower control position is selected (p. 20, figure 8).
To use the switch in the lower controls panel:
1.
Loosen the screws (lower controls, screws A and B) to detach the protecting plate
2.
Turn the override switch clockwise and hold it turned
3.
Turn on combustion engine or electric motor
4.
Lower the booms
slowly with caution
5.
Release the override switch
6.
Turn off engine / motor
7.
Attach the override switch’s protecting pl
ate (screws A and B)
Emergency lowering without power to logic controller
In a situation when the logic controller of the access platform has lost power or does not
function for any reason, there is a secondary emergency lowering method in addition to the
normal emergency lowering procedure described in chapter 6.1. The method works by using a
Содержание 135 NEO
Страница 1: ...Operator and Service manual Version 7 2020 July 2020 ...
Страница 9: ...9 Main dimensions Figure 2 135 NEO Main dimensions side Figure 3 135 NEO main dimensions rear ...
Страница 10: ...10 Reach diagram and support dimensions Figure 4 Reach diagram Figure 5 Support dimensions ...
Страница 59: ...59 Figure 37 Load control of the platform Figure 38 Boom position monitoring ...
Страница 60: ...60 Figure 39 Platform levelling monitoring Figure 40 Outrigger monitoring ...
Страница 61: ...61 Figure 41 Transport position monitoring Figure 42 Prevention of drive function ...
Страница 62: ...62 Figure 43 Selection of the platform control position Figure 44 Selection of the lower control position ...
Страница 63: ...63 Figure 45 Selection of the remote control position Figure 46 Platform emergency stop button override ...
Страница 64: ...64 Figure 47 Platform load monitoring override Figure 48 Override of Safety Functions ...