- 86 -
Spirit GE User Manual
7) Take the unattached end of the ¼” air tubing (other end already connected to air compressor)
and connect it to the air tube connector on the air assist valve. Make sure you press down on
the air tube fastener when inserting the ¼” air tubing, to form a tight, secure attachment as
indicated in the diagram below.
8) Congratulations, you have finished setting up the air compressor. Make sure you have the
proper SmartAIR nozzle installed (depending on your application), before you turn on and
utilize the air compressor.
OPERATION:
1) Switch on the air compressor unit and make sure that the airflow regulator on the air assist
valve is opened (turn clockwise to increase the airflow, counter-clockwise to decrease the
airflow). The air nozzle under the laser head should emit a steady flow of air.
With the SmartAIR nozzle and air compressor properly installed and operating, all configurations and
settings relating to air-assist functions are controlled through the LaserPro Spirit GE print driver and
hardware control panel. Please refer to the LaserPro Spirit GE print driver and graphic control panel
sections of this manual for details on how to enable and configure air-assist functionalities.
Power Cord A
Socket
Power Cord B
Socket
Air Flow Regulator:
Turn Clockwise
to increase
airflow
Turn Counter-
Clockwise to
decrease
airflow
Air Tube
Fastener
Air Tube
Connector