- 51 -
Spirit GE User Manual
SmartGUARD Page
After hardware installation, please enter the function menu on the control panel to enable the
SmartGUARD fire alarm.
SmartGUARD
:
Enable/Disable
Sensitivity
:
1,3,5,7,9 seconds
SmartGUARD
:
Press directional key (left or right) to enable the SmartGUARD device or disable it.
Sensitivity
:
Press directional key (left or right) to set the sensitivity of SmartGUARD. There are five
sensitivity settings (1,3,5,7,9 seconds) that can be selected. Sensitivity is defined by the delay
time from when a fire is detected until the fire alarm alerts user of fire and automatically shuts
down the system. For example, if the sensor delays switch is set to the 3 second position, the
SmartGUARD will start an alarm and automatically shutdown the laser system after detecting a
fire for 3 seconds.
SmartGUARD Setting Page
Relevant Buttons
Function
F1 (Back)
Back to previous page
F4 (Save)
Save your current settings
Y
/
Z
Directional
Adjust the value for that selection
U
/
V
Directional
Scroll through the menu selections
Start / Stop
Back to Main Work Page
Auto Focus
Initiate the auto focus function
▲
/
▼
Manual Focus
Buttons
Manually adjust the height of the work table (Z-
axis)
Select <
SmartGUARD
Setting
> from the menu
Main Work Page
Press
F4
☼
Navigating to this page:
Functions Page
Select <
Machine Setting
>
from the menu
Machine Setting Page
SmartGUARD Setting
Page