Page 22
Start-up
Deadly risk!
Do not operate the equipment with damp hands!
Take caution with live components!
Risk of injury!
Take caution with heated components!
Before start-up
The connecting hose is not yet connected to the consumer
load .
• Open cabinet door
• Close shut-off valve "cable pressure" (
9
).
Switch on signal voltage
• Turn on main fuse switch (
6
) by pressing the green button.
9
5
6
Check indications of MFR (73)
• Green Signal-LED „
DC
“ (
47
) illuminates.
• Red Signal-LED „
N
“ (
51
) illuminates.
• Red Signal output-LEDs (
64 - 66
) illuminate.
49
51
47 64-66
Set the equipment into operation / charge equipment
Main switch signal voltage DC (6) is switched on
Turn motor protective switch (5) to "I"
• The compressor starts.
Check indications of Minidisplay (14)
• All LEDs of the 5 digit numeric display (
38
) flash once (indica-
tion 88888).
• All LEDs of the 8 digit humidity display (
39
) flash once.
• All Signal-LEDs (
40-43
) flash once.
subsequently:
• The green Signal-LED „
DC
“ (
40
) illuminates.
• The green Signal-LED „
F-on
“ (
43
) illuminates (humidity moni-
toring is active).
44 38 39 45
46 40-43
• The LEDs of the 5 digit numeric display (
38
) indicate the actual operating hours of the system.
• The LEDs of the 8 digit humidity display (
39
) indicate the actual humidity value of the pressurised air.
Содержание RTS 1000D
Страница 43: ...Page 43 Compressor VD 7 2 RTS 1000D and VD 28 2 RTS 2600D B...
Страница 45: ...Page 45 Compressor VD 50 4 RTS 5200D...
Страница 57: ...Compressor VD 7 2 and VD 28 2 Page 57...
Страница 59: ...Page 59 Compressor VD 50 4...
Страница 61: ...Page 61 Pneumatics diagram RTS 1000D RTS 2600D and RTS 5200D no 073445 072...
Страница 63: ...Page 63 Circuit and wiring diagram RTS 1000D RTS 2600D und RTS 5200D no 073659 000...
Страница 65: ...Page 65 Circuit and wiring diagram RTS 1000D RTS 2600D und RTS 5200D no 073586 000...
Страница 66: ...Page 66...
Страница 67: ...Page 67...