Page 27
Restore operating status
• Close safety valve "high pressure" (
25
).
• Set pressure reducer (
7
) to cable pressure (see the following chapter).
Check and set cable pressure (pressure reducer)
Setpoint value cable pressure
• is set according to the customer order.
Check cable pressure
• Switch on operating voltage.
• Close shut-off valve (
9
).
• Manometer "cable pressure" (
12
) must display
12
the required cable pressure.
otherwise :
Set cable pressure to the value in keeping with the order
• Operating voltage is switched on.
• shut-off valve (
9
) is closed.
• Turn the setting screw of pressure reducer (
7
) with screw
driver until the manometer "cable pressure" (
12
) displays
the cable pressure according to the order.
9
7
Warning!
The cable pressure setting range is between 0 and 1 bar.
The safety valve "cable pressure" opens independently of the preset cable pressure (0-1 bar)
at 0.2 bar over the cable pressure according to the order.