Page 24
In order to get immediate humidity moni-
toring, the "F-off" operation must be
overridden:
• Press button „F-Off“ (
44
) of the Minidisplay
or (
67
) of the MFR for approx. 5 seconds.
• The green LEDs „F-On“ (
43
) on the Minidis-
play and (
54
) on the MFR illuminate again.
• Close safety valve "high pressure" (
25
).
• Then carry out function testing.
• Remount connecting block cover (
11
).
MFR
52 48 54
67 49 51
59-61
62
47
63-65
The humidity monitoring activates itself automatically after approx. 2 operating hours of the compres-
sor, if the „F-off“ operaton is not determined manually.
Switching the motor protective switch (
5
) off and on again, terminates the „F-off“ operation also. This proce-
dure resets the MFR by breaking its power supply.